What are the safety protection measures for high and low temperature and low pressure test chambers?
Publish Time: 2024-10-29
As a test equipment that simulates extreme environmental conditions, the safety protection measures of the high and low temperature and low pressure test chamber are crucial. The following are some common safety protection measures:
1. Equipment design and manufacturing safety
Structural strength: The structural design of the test chamber must meet certain strength requirements and be able to withstand the stress caused by pressure changes and temperature changes during the test process to ensure the stability and safety of the equipment in long-term use.
Sealing performance: The design of the sealing strips and doors of the test chamber must ensure good sealing performance to prevent gas leakage and ensure the accuracy and stability of the test environment.
2. Electrical safety
Electrical circuits and control systems: The electrical circuits and control systems of the test chamber need to be checked regularly to ensure that the wires, plugs, etc. are not aging or damaged, and to prevent safety hazards such as electrical fires.
Overload protection: The equipment should be equipped with an overload protection device. When the current exceeds the rated value, it can automatically cut off the power supply to prevent the equipment from overheating, damage or fire.
Grounding protection: The test chamber should have a good grounding system to ensure that the equipment can safely conduct static electricity and other charges into the ground during operation to prevent electric shock accidents.
3. Operational safety
Operational training: All personnel using high-temperature and low-pressure test chambers should receive professional operation training and understand the working principle, operation method and safety precautions of the equipment. Untrained personnel shall not operate the equipment without authorization.
Personal protection: When conducting high-temperature and low-pressure tests, operators should wear appropriate protective equipment, such as protective glasses, gloves, etc., to avoid direct contact with the surface of the equipment under extreme temperature conditions to prevent burns or frostbite.
Emergency stop switch: The equipment should be equipped with an emergency stop switch to immediately cut off the power supply in an emergency to ensure the safety of personnel and equipment.
4. Test environment safety
Sample placement: The placement of the test sample should be a certain distance away from the box wall to avoid blocking the air outlet and return air outlet, and ensure the uniformity and stability of the test environment. At the same time, the sample should be placed on a dedicated sample rack to prevent damage caused by slipping or tipping.
Prohibition of flammable and explosive items: It is prohibited to place flammable and explosive items in the test chamber to prevent fire or explosion accidents during the test.
5. Maintenance and care
Regular maintenance: The test chamber should be regularly maintained, including cleaning the internal and external surfaces of the equipment, checking and tightening the connectors and bolts, replacing filters, etc., to ensure the normal operation of the equipment and extend its service life.
Troubleshooting and repair: When the equipment fails, it should be stopped in time to check and troubleshoot the fault to prevent the fault from expanding or causing a safety accident.
The safety protection measures of the high and low temperature and low pressure test chamber cover equipment design and manufacturing, electrical safety, operational safety, test environment safety, maintenance and care, etc. These measures together constitute the safety protection system of the equipment, ensuring the accuracy and safety of the test process.