products
HomeOur ServicesGas Collection Tester

Gas Collection Tester

There are three ways to trigger thermal runaway of power batteries: overcharging, heating, and acupuncture. This device can bear three triggering methods. After the battery thermal runaway, this device can collect the gas released by the battery for analysis.
The main body of this device is a pressure-bearing closed container that can withstand high pressure to ensure the safety of test personnel. The device can automatically collect and record the temperature and voltage information of the battery, and can also record video images.
Patent number: ZL202023172183.5
ZL202120740396.9

Device Model

RJD-QTSJ-86L

RJD-QTSJ-476L

Overall dimensions W*D*H(mm)

W1300*D1000*H1250mm

W1600*D1500*H1700mm

Pressure vessel materials

304 Stainless Steel

SUS304 stainless steel

Pressure vessel size

Inner diameter 430mm*height 600mm

Inner diameter 900mm*depth 750mm

Pressure vessel structure

Vertical

Horizontal

Container pressure resistance

Normal pressure-1.5Mpa

Vacuum-6Mpa

Thermal runaway triggering method

Overcharge, heating

Overcharge, heating, acupuncture

Temperature range in container

Normal temperature

20-80℃

Heating rate

/

20℃-80℃,<2H

Acupuncture power source

/

Servo Electric Cylinder

Needle puncture speed

/

0.1mm-80mm/s

Needling force range

/

0.1KN~10KN

Heating power

Support 0-3000W

Heating control

Power mode:

Heating capacity: Maximum DC100V, 30A

Heating power: Support 30-3000W

Heating control: The upper computer controls the programmable power supply to control the heating plate;
the output power can be set arbitrarily by the computer (the actual power is determined by the heating plate)

Control judgment: Use temperature 1-5 channels and voltage 1-5 channels as logic judgment

Overcharge current carrying

200A, 1 set of terminal blocks

Data collection

Configuration options

Standard Configuration

Upgrade Configuration

High-speed acquisition configuration

Voltage acquisition

Single cell voltage

0-5V/0-10V

0-10V

±10V

Number of channels

Standard 4 channels

Standard 4 channels

Standard 4 channels

Acquisition rate

100Hz

10KHz

10KHz/50KHz

Collection accuracy

±0.15%F.S

±0.15%F.S

±0.05%F.S

High Voltage

0-100V、0-300V

0-100V、0-300V

±120V、±400V、±1200V

Number of channels

Standard 4 channels

Standard 4 channels

Standard 4 channels

Acquisition rate

100Hz

10KHz

10KHz/50KHz

Collection accuracy

±0.3%F.S

±0.3%F.S

±0.05%F.S

Temperature collection

Acquisition range

0-1200℃

0-1200℃

0-1200℃

Number of channels

Standard 4 channels

Standard 8 channels

Standard 8 channels

Acquisition rate

10Hz

75Hz

100Hz

Collection accuracy

±2℃

±1.5℃

±1℃

Power supply

AC380V

Power

5KW

30KW

×

Contact Us

captcha