Device Model | RJD-BS-F-2C |
Overall dimensions W*D*H(mm) | W4100×D 5400×H 2600 mm |
Inner box size | W 2500×D2000×H500 mm |
Water tank | 800*900*600mm(Depth × Width × Height) (For reference only) |
Temperature range | (High temperature box RT+10~150℃) (Low temperature tank ice water temperature 0~4℃) |
Temperature fluctuation | ≤±0.5℃ |
Temperature uniformity | 2℃ |
Temperature deviation | ≤±2℃ |
Heating and cooling rate | High temperature box ℃/min (RT+10~150℃, 3℃/min average throughout the process); low temperature tank cooling rate: 25℃~0℃, 0.5℃/min average throughout the process) |
Test medium | Deionized water or +5%NaCl+3% Arizona fine dust mixture. |
Sample size | Meet sample sizes from 100mm×100mm×50mm to 3000mm×1800mm×800mm; |
Ice tank system | The nozzle slides and the pull-rod nozzle is used; the angle and distance of the nozzle are adjusted according to the size of the sample. |
Meet the standards | Test method (temperature curve, test frequency, cycle, etc.) Meet the standards: GB/T 28046.4-2011 (ISO 16750-4: 2006), VW80000: 2009-10 |