Model | RJD-JSC-12 |
Workshop size (mm) | 3000*2000*2000, studio volume is about 12m³ |
Outer box size (mm) | About 4050*2675*3075 |
Dust baking temperature range | RT+10℃~60℃ (heating dust baking system) |
Humidity in the test chamber | Normally wet (displayable, uncontrollable) |
Dust dehumidification | Electric heating dehumidification |
Air flow rate | No more than 2m/s |
Dust emission method | Dust blowing from top to bottom (vertical), dust blowing time can be controlled by program |
Blowing dust | Talcum powder |
Blowing method | Vertical airflow from top to bottom |
Time Control | 0s~99h59m59s adjustable |
Lighting | 4 LED explosion-proof and moisture-proof cold light source lamps for better observation of the test product in the box |
Static elimination | The inner wall of the box is equipped with an anti-static device to reduce the amount of dust attached to the wall of the box |
Talc dosage | 2kg/m³ (Use frequency shall not exceed 20 times) |
Talc Specifications | The dried talcum powder should be filtered through a metal square mesh sieve. The wire diameter is 50 μm and the mesh size is 75 μm. |
Test hole | The side of the box is equipped with 2 φ100mm detection lead holes, which can be reliably sealed |
Test sample placement platform | Mesh rack, load-bearing capacity 1.5T, forklift space should be reserved at the bottom of the equipment to facilitate the insertion and removal of samples |
Platform pulley | The pulley can be moved to adjust the placement, and the position can be fixed with bolts (maximum weight can withstand ≧1000Kg) |
Chamber material | SUS201 mirror stainless steel |
Outer box material | SUS201 stainless steel |
Door Type | Hinged double door, good sealing (two observation windows on the door, with manual dust scraper brush) |
Box structure | Conventional box (non-sunk type) |
Control method | PLC+Touch Screen |
Vacuum system | When the vacuum system draws negative pressure from the sample, it can reach -2kPa; |
A PU air pipe with specifications of 8 (outer diameter) × 5 (inner diameter) × 1500 (length) needs to be introduced into the studio, | |
Data Export | Test data can be exported via USB flash drive |
Supply voltage | AC380V±10% 50HZ±10% |
Meet the standards | 1. GB/T4208-2017-13.4 Enclosure protection grade (IP code) 2. GB/T2423.37-2006-La2 Basic environmental test procedures for electrical and electronic products Test La2 Sand and dust test method 3. IEC 60068-2-68-La2 Sand and dust test method |