Model | RJD-HLTLP-252S | RJD-HLTLP-408S | RJD-HLTLP-1000S | |
Inner box size(mm) | W600*H750*D500 | W800*H900*D700 | W1000*H1000*D1000 | |
Outer box size(mm) | W1200*H1800*D1900 | W1400*H1950*D2100 | W1600*H2050*D2400 | |
Technical Parameters | Temperature range | -20~150℃ | ||
Temperature deviation | ≤±2℃ (normal pressure and no load) | |||
Temperature gradient | ≤2℃ (normal pressure and no load) | |||
Temperature fluctuation | ±0.5℃ (normal pressure and no load) | |||
Heating and cooling rate | 0.8~1.2℃/min | |||
Pressure range | 101.3Kpa~1Kpa | |||
压力偏差 | 常压~40Kpa:±1.8Kpa; 40Kpa~4Kpa:±4.5Kpa; 4Kpa~1Kpa:±0.1Kpa; | |||
Buck-boost time | Pressure reduction rate: 101Kpa~1.0Kpa≤30min (when the box is dry) Pressure increase recovery rate: ≤10Kpa/min | |||
Control System | Controller | The touch-type PLC architecture controller has multiple groups of intelligent PID control. | ||
Cabinet Features | Inner box material | SUS304 stainless steel, weld polishing. Steel plate thickness 5.0MM, the outer side of the inner box is reinforced with steel plate strips, | ||
Outer box color | Galvanized sheet powder high temperature spray | |||
Pressure bearing method | Internal pressure | |||
Observation window | Double-layer vacuum glass; electric heating for door frame (automatic adjustment, automatically shutting off window frame heating when the temperature inside the box is high) | |||
External Interface | The current, temperature and wiring ports can be reserved as required, while ensuring the sealing of the box | |||
Illumination | The lighting strip is installed on the observation window of the box door. The LED light strip can illuminate the entire test space.Only light can be seen outside the box, but no light can be seen.This can avoid glare problems and solve lighting problems. | |||
Vacuum Pump | A stainless steel chuck-type quick interface is welded on the side of the box, which can be used to quickly connect to the external pipeline. | |||
Manual inflation valve | The manual pressure relief valve connects the inside and outside of the box to achieve pressure balance inside and outside the box, and the box door can be opened. | |||
Automatic pressure relief | When the pressure holding time is reached, the pressure can be automatically released | |||
Cooling method | Air Cooling | |||
Protective devices | Compressor overheat protection, compressor overload protection; Compressor high and low pressure protection; Box overtemperature protection; Door closing protection; Phase sequence protection; Circulating fan protection; Heating overtemperature protection; Magnetic fluid water shortage protection; Cooling water underpressure protection; Three-color indicator alarm system; Other function alarms | |||
Supply voltage | AC380V±10% 50HZ±10% |