Features: | ◆Adopt color touch screen control, friendly interface, and parameter recording function; ◆Ultra-low defrosting times, greatly improving test efficiency; ◆Basket conversion time is less than 10 seconds, and temperature recovery time is less than 5 minutes; ◆R232, R485 output interface, realize multiple remote monitoring and control; ◆Error information is displayed in real time, easy to troubleshoot. | ||||||
Model | RJD-TS-75DB | RJD-TS-108DB | RJD-TS-256DB | ||||
Inner box size(mm) | W500*D500*H300 | W600*D600*H300 | W800*D800*H400 | ||||
Dimensions(mm) | W1500*D2150*H2200 | W1650*D2250*H2220 | W1950*D2600*H2200 | ||||
Shock temperature | Low temperature shock range | -10℃~-40℃ | -10℃~-55℃ | -10℃~-40℃ | -10℃~-55℃ | -10℃~-40℃ | -10℃~-55℃ |
High temperature shock range | 60℃~150℃ | ||||||
Preheating zone heating rate | 5℃/min | ||||||
Precooling zone cooling rate | 2℃/min | ||||||
Precooling zone temperature range | -10℃~-60℃ | -10℃~-70℃ | -10℃~-60℃ | -10℃~-70℃ | -10℃~-60℃ | -10℃~-70℃ | |
Preheating temperature range | 60℃~200℃ | ||||||
Dwell time | 30min | ||||||
Recovery time | 5min to restore to within ±2℃ | ||||||
Temperature fluctuation | ≤1℃ | ||||||
Basket changeover time | ≤10s | ||||||
Structural parameters | Inner box material | SUS304 stainless steel | |||||
Outer box material | Galvanized sheet powder high temperature spray | ||||||
Insulation material | Environmentally friendly hard polyurethane insulation material, thickness 100mm | ||||||
Refrigeration system | Including: compressor, condenser, oil separator, filter dryer, solenoid valve, expansion valve and other refrigeration components | ||||||
Controller | Touch-type PLC architecture controller with multiple groups of intelligent PID control | ||||||
Structural advantages | Adopting a vertical, hot and cold two-box structure, using a basket to quickly transfer the test sample to the test area, the purpose of hot and cold shock test is achieved. | ||||||
Protective devices | Compressor overload; compressor oil shortage; compressor overpressure; heater leakage protection; heater short circuit and overload protection; heating system overtemperature protection; test space ultra-high temperature/ultra-low temperature protection (digital display); fan motor overheating; main power phase sequence and phase loss protection; overload and short circuit protection; three-color light alarm device; emergency stop control; basket position alarm; test chamber shell grounding protection. | ||||||
Communication Protocol | Open communication protocol can be used with other devices | ||||||
Supply voltage | AC380V±10% 50HZ±10% |