Energy regulation measures are adopted to adjust the refrigeration capacity of the system according to different cooling speeds and temperature ranges while ensuring the main technical indicators of the test chamber, energy regulation measures are added, such as evaporation temperature regulation, energy regulation, and hot gas bypass energy regulation to ensure that the energy consumption of the equipment is reduced while meeting the main technical indicators,
Advanced PID regulation technology is used to greatly reduce the energy consumption of the machine. According to the strict water-electricity separation design method, the safety of the machine operation is effectively guaranteed,
Imported core components and excellent technology ensure the long-term working stability of the compressor,
The equipment has the function of recycling circulating water and switching to external drainage, which can be freely selected according to the customer's water quality conditions.

model

RJD-HLT-252D

RJD-HLT-408D

RJD-HLT-800D

Single layer inner box size(mm)

W600*D700*H600

W800*D850*H600

W1000*D800*H1000

Outer box size(mm)

W1300*D1800*H1950

W1500*D1700*H2150

W1740*D2300*H1900

Structural method

Double-layer box, with a working room on the top and bottom, each with independent temperature control

Double-layer box, with a working room on the top and bottom, each with independent temperature control

Double-layer box, with a working room on the top and bottom, each with independent temperature control

Temperature range

20℃~+150℃
40℃~+150℃
70℃~+150℃

20℃~+150℃
40℃~+150℃
70℃~+150℃

20℃~+150℃
40℃~+150℃
70℃~+150℃

Heating rate

1~5℃/minute (customizable)

Cooling rate

1~5℃/minute (customizable)

Temperature fluctuation

±0.3℃

±0.3℃

±0.3℃

Temperature uniformity

≤2℃(No-load, steady state)

≤2℃(No-load, steady state)

≤2℃(No-load, steady state)

Temperature deviation

±1.0℃

±1.0℃

±1.0℃

Observation window

W300XH400MM (customizable), three-layer vacuum tempered glass

Inner box material

SUS304 stainless steel, thickness 1.0mm, can be sprayed with Teflon insulation

Outer box material

Galvanized sheet powder high temperature spray

Test terminal or lead hole

Wiring ports and lead ports can be reserved as required

Cooling method

Air cooling/water cooling optional

Control method

Touch screen programmable PLC, with USB interface, RS485 interface can be connected to computer control, dedicated network control software, convenient remote monitoring, data collection

Communication Protocol

Open communication protocol can be used with other devices

Safety protection

Automatic explosion-proof pressure relief device, explosion-proof chain, three-color light alarm device, remote control, smoke exhaust device, fire extinguishing device, emergency stop, power supply protection, etc.

Supply voltage

AC380V±10% 50HZ±10%

Reference Standards

GB/T 2423.1—2008 Basic environmental test procedures for electrical and electronic products Test A: Low temperature test

GB/T 2423.2—2008 Basic environmental test procedures for electrical and electronic products Test B: High temperature test

GJB 150.3A-2009 Military equipment laboratory environmental test methods Part 3: High temperature test

GJB 150.4A-2009 Military equipment laboratory environmental test methods Part 4: Low temperature test

GB 10592-2008 Technical conditions for high and low temperature test chambers

GB/T 5170.1-2008 Basic parameter verification methods General

GB/T 5170.2-2008 Electrical and electronic products environmental test equipment inspection methods Temperature test equipment

×

Contact Us