Device Model | RJD-DL-HT-500A-C1 | RJD-DL-HT-1000A-C1 | RJD-DL-RT-3000A | ||
Short circuit mode | High temperature or normal temperature | High temperature or normal temperature | Normal temperature | ||
Number of short-circuit channels | 1/2/4/6 (customizable) | 1/2/4/6 (customizable) | 1/2/4/6 (customizable) | ||
Thermostat Channel Number | 1/2/4/6 (customizable) | 1/2/4/6 (customizable) | 1/2/4/6 (customizable) | ||
Overall dimensions W*D*H(mm) | W800mm*D800mm*H1650mm | W800mm*D800mm*H1650mm | W800*D900*H1250mm | ||
Power supply | AC220V/three-phase five-wire | AC220V/three-phase five-wire | AC220V/three-phase five-wire | ||
Power | 10KW | 10KW | 15KW | ||
Rated short circuit current | 500A | 1000A | 3000A | ||
Equipment internal resistance | <5mΩ | <5mΩ | <1mΩ | ||
Temperature range | RT+10℃~100℃ | RT+10℃~100℃ | Optional | ||
Heating rate | 3℃/min | 3℃/min | / | ||
Resistance | 5mΩ, 10mΩ, 40mΩ, 80mΩ (customizable) | 5mΩ, 10mΩ, 40mΩ, 80mΩ (customizable) | 80mΩ (customizable) | ||
Arc extinguishing device | Import switch | Import switch | 采用进口电动大电流开关(自带灭弧功能、无需抽真空、拥有国家3C检测报告) | ||
Mechanical life | ≥10000次 | ≥10000次 | ≥10000次 | ||
Control method | Remote PC+on-site touch screen+remote control | ||||
Cooling method | Air Cooling | ||||
Data collection | Configuration options | Standard Configuration | Upgrade Configuration | High-speed acquisition configuration | |
Current acquisition | Acquisition range | 0~500A | 0~1000A | 0~3000A | |
Number of channels | 1 channel (multiple channels possible) | 1 channel (multiple channels possible) | 1 channel | ||
Acquisition rate | 100Hz | 10KHz | 10KHz | ||
Collection accuracy | ±0.35%F.S | ±0.35%F.S | ±0.15%F.S | ||
Voltage acquisition | Single cell voltage | 0-5V/0-10V | 0-5V/0-10V | ±10V | |
Number of channels | Standard 4 channels | Standard 4 channels | Standard 8 channels | ||
Acquisition rate | 100Hz | 10KHz | 10KHz | ||
Collection accuracy | ±0.15%F.S | ±0.15%F.S | ±0.05%F.S | ||
High Voltage | 0-100V | 0-100V | ±120V | ||
Number of channels | Standard 3 channels | Standard 3 channels | Standard 8 channels | ||
Acquisition rate | 100Hz | 10KHz | 10KHz/50KHz | ||
Collection accuracy | ±0.3%F.S | ±0.3%F.S | ±0.05%F.S | ||
Temperature collection | Temperature range | 0-1200℃ | 0-1200℃ | 0-1200℃ | |
Number of channels | Standard 4 channels | Standard 8 channels | Standard 8 channels | ||
Acquisition rate | 10Hz | 75Hz | 100Hz | ||
Collection accuracy | ±2℃ | ±1.5℃ | ±1℃ | ||
Explosion-proof box | Optional, customizable normal temperature/high and low temperature | ||||
Video surveillance | Optional |