Device Model | RJD-ZJ-RT-2T-300D | RJD-ZJ-RT-4T-300D | RJD-ZJ-RT-6T-300D | ||
Overall dimensions W*D*H(mm) | W1700mm*D1600mm*H2050mm | W1700mm*D1600mm*H2050mm | W1700mm*D1600mm*H2050mm | ||
Power supply | 380V/three-phase five-wire | 380V/three-phase five-wire | 380V/three-phase five-wire | ||
Power | 5KW | 6KW | 10KW | ||
Pressure range | 1KN-20KN | 2KN-40KN | 3KN-60KN | ||
Pressure accuracy | ±0.5KN | ±0.5KN | ±0.5KN | ||
Temperature range | Normal temperature (high temperature/low temperature can be customized) | Normal temperature (high temperature/low temperature can be customized) | Normal temperature (high temperature/low temperature can be customized) | ||
Pressure control method | All-electric servo | All-electric servo | All-electric servo | ||
Equipment structure | Four-column structure | Four-column structure | Four-column structure | ||
Effective test space W*D*H(mm) | 600*600*600mm (customizable size) | 600*600*600mm (customizable size) | 600*600*600mm (customizable size) | ||
Displacement stroke | 0-300mm (customizable) | 0-300mm (customizable) | 0-300mm (customizable) | ||
Displacement accuracy | Extrusion: ±0.1mm | Extrusion: ±0.1mm Acupuncture: ±0.05mm | Extrusion: ±0.1mm Acupuncture: ±0.05mm | ||
Extrusion speed range | 0.01mm-15mm/s | 0.01mm-15mm/s | 0.01mm-15mm/s | ||
Acupuncture speed range | 0.01mm-80mm/s | 0.01mm-80mm/s | 0.01mm-80mm/s | ||
Pressure sampling rate | 100Hz | 100Hz | 100Hz | ||
Test conditions | Force/displacement (deformation)/voltage One of the three or any combination | Force/displacement (deformation)/voltage One of the three or any combination | Force/displacement (deformation)/voltage One of the three or any combination | ||
Control method | Touch screen/remote PC control | Touch screen/remote PC control | Touch screen/remote PC control | ||
Video surveillance | Optional | Optional | Optional | ||
Spraying device | Optional | Optional | Optional | ||
Data collection | Configuration options | Standard Configuration | Upgrade Configuration | High-speed acquisition configuration | |
Voltage acquisition | Single cell voltage | 0-5V/0-10V | 0-10V | ±10V/±120V | |
Number of channels | Standard 4 channels | Standard 4 channels | Standard 8 channels | ||
Number of channels | 100Hz | 10KHz | 10KHz/50KHz | ||
Collection accuracy | ±0.15%F.S | ±0.15%F.S | ±0.05%F.S | ||
Number of channels | Standard 4 channels | Standard 4 channels | Standard 8 channels | ||
Number of channels | 100Hz | 10KHz | 10KHz | ||
Temperature collection | Acquisition range | 0-1200℃ | 0-1200℃ | 0-1200℃ | |
Number of channels | Standard 4 channels | Standard 4 channels | Standard 8 channels | ||
Number of channels | 10Hz | 75Hz | 100Hz | ||
Collection accuracy | ±2℃ | ±1.5℃ | ±1℃ |