Device Model | RJD-ZJ-RT-20T-1000D | RJD-ZJ-RT-30T-1000D | RJD-ZJ-RT-100T-3000D | ||
power | 8KW | 10KW | 12KW | ||
power supply | 380V/three-phase five-wire | 380V/three-phase five-wire | 380V/three-phase five-wire | ||
Overall dimensions W*D*H(mm) | W3400mm*D1600mm*H1650mm | W3400mm*D1600mm*H1650mm | W6300mm*D1820mm*H1500mm | ||
Stress test range | 20KN-200KN | 30KN-300KN | 50KN-1000KN | ||
Pressure accuracy | ±1.5KN | ±1.5KN | ±1.5KN | ||
Pressure control method | Servo oil pressure | Servo oil pressure | Servo oil pressure | ||
Equipment structure | C type/four columns and three boards (optional) | C type/four columns and three boards (optional) | C type/four columns and three boards (optional) | ||
Effective test space W*D*H(mm) | W1000mm*D1000mm*H1000mm (customizable size) | W1000mm*D1000mm*H1000mm (customizable size) | L3000mm X W2000mm (height is not limited by equipment, customizable size) | ||
Lifting platform | 2 pieces, size 300*1000mm | 2 pieces, size 200*1400mm | 4, size 500*1400mm, platform spacing 30mm, each platform bearing 2000KG | ||
temperature range | Normal temperature/high and low temperature (optional) | Normal temperature/high and low temperature (optional) | Normal temperature/high and low temperature (optional) | ||
Displacement stroke | 0-1000mm (customizable) | 0-1000mm (customizable) | 0-1500mm (customizable) | ||
Displacement accuracy | Extrusion: ±0.1mm | Extrusion: ±0.1mm | Extrusion: ±0.1mm | ||
Acupuncture: ±0.05mm | Acupuncture: ±0.05mm | Acupuncture: ±0.05mm | |||
Extrusion speed range | 0.1mm-15mm/s | 0.1mm-15mm/s | 0.1mm-15mm/s | ||
Acupuncture speed range | 0.1mm-150mm/s | 0.1mm-150mm/s | 0.1mm-150mm/s | ||
Pressure sampling rate | 100Hz | 100Hz | 100Hz | ||
Test conditions | Force/displacement (deformation)/voltage or any combination thereof | Force/displacement (deformation)/voltage or any combination thereof | Force/displacement (deformation)/voltage or any combination thereof | ||
control method | Touch screen/remote PC control | Touch screen/remote PC control | Touch screen/remote PC control | ||
Video Surveillance | Optional | Optional | Optional | ||
Spraying device | Optional | Optional | Optional | ||
data collection | Configuration options | Standard configuration | Upgrade Configuration | High-speed acquisition configuration | |
Voltage acquisition | Single cell voltage | 0-5V/0-10V | 0-10V | ±10V | |
Number of channels | Standard 4 channels | Standard 4 channels | Standard 8 channels | ||
Acquisition rate | 100Hz | 10KHz | 10KHz | ||
Collection accuracy | ±0.15%FS | ±0.15%FS | ±0.05%FS | ||
high voltage | 0-100V, 0-300V | 0-100V, 0-300V | ±100V, ±500V, ±1200V | ||
Number of channels | Standard 4 channels | Standard 4 channels | Standard 8 channels | ||
Acquisition rate | 100Hz | 10KHz | 10KHz | ||
Collection accuracy | ±0.3%FS | ±0.3%FS | ±0.05%FS | ||
Temperature collection | Acquisition range | 0-1200℃ | 0-1200℃ | 0-1200℃ | |
Number of channels | Standard 4 channels | Standard 8 channels | Standard 8 channels | ||
Acquisition rate | 10Hz | 75Hz | 100Hz | ||
Collection accuracy | ±2℃ | ±1.5℃ | ±1℃ |