products
HomeOur ServicesNeedle Puncture Tester

Needle Puncture Tester

The battery puncture extrusion tester is mainly used to simulate the safety and reliability testing of batteries after being punctured or extruded under different conditions.
Pressure, displacement, voltage drop, and temperature can be used as control variables alone or in combination. The test will be stopped when any condition reaches the set value.
It has pressure, displacement, speed, type variable, temperature, and voltage data recording and real-time display of data curves.
It can set multi-step extrusion or multi-step puncture functions.
The test chamber is composed of flame-retardant components such as high temperature resistance and corrosion resistance; the reinforced design can effectively isolate the damage caused by fire and explosion during the test.
Patent number: ZL201920401188.9

Device Model

RJD-ZJ-RT-5T-1000D

RJD-ZJ-RT-10T-1000D

RJD-ZJ-RT-20T-1000D

DimensionsW*D*H(mm)

W4000*D1300*H2100mm

W4300*D1500*H2100mm

W4500*D1500*H2100mm

Pressure Range

5KN-50KN

5KN-100KN

10KN-200KN

Pressure accuracy

±0.5KN

±0.78KN

±0.78KN

Pressure control method

All-electric servo

All-electric servo

All-electric servo

Equipment structure

C type/four columns and three boards

C type/four columns and three boards

C type/four columns and three boards

Effective test spaceW*D*H(mm)

1000*600*600 (customizable size)

1000*600*600 (customizable size)

1000*600*600 (customizable size)

Temperature range

Normal temperature/high and low temperature

Normal temperature/high and low temperature

Normal temperature/high and low temperature

Displacement stroke

0-1000mm (customizable)

0-1000mm (customizable)

0-1000mm (customizable)

Displacement accuracy

Extrusion: ±0.1mm

Acupuncture: ±0.05mm

Extrusion: ±0.1mm

Acupuncture: ±0.05mm

Extrusion: ±0.1mm
Acupuncture: ±0.05mm

Extrusion speed range

0.01mm-15mm/s

0.01mm-15mm/s

0.01mm-15mm/s

Acupuncture speed range

0.01mm-80mm/s

0.1mm-80mm/s

0.01mm-80mm/s

Pressure sampling rate

100Hz

100Hz

100Hz

Test conditions

Force/displacement (deformation)/voltage

One of the three or any combination

Force/displacement (deformation)/voltage

One of the three or any combination

Force/displacement (deformation)/voltage

One of the three or any combination

Control method

Touch screen/remote PC control

Touch screen/remote PC control

Touch screen/remote PC control

Video Surveillance

Optional

Optional

Optional

Spraying device

Optional

Optional

Optional

data collection

Configuration options

Standard configuration

Upgrade Configuration

High-speed acquisition configuration

Voltage acquisition

Single cell voltage

0-5V/0-10V

0-10V

±10V

Number of channels

Standard 4 channels

Standard 4 channels

Standard 8 channels

Acquisition rate

100Hz

10KHz

10KHz

Collection accuracy

±0.15%F.S

±0.15%F.S

±0.05%F.S

High voltage

0-100V、0-300V

0-100V、0-300V

±120V、±400V、±1200V

Number of channels

Standard 4 channels

Standard 4 channels

Standard 8 channels

Acquisition rate

100Hz

10KHz

10KHz

Collection accuracy

±0.3%F.S

±0.3%F.S

±0.05%F.S

Temperature collection

Acquisition range

0-1200℃

0-1200℃

0-1200℃

Number of channels

Standard 4 channels

Standard 8 channels

Standard 8 channels

Acquisition rate

10Hz

75Hz

100Hz

Collection accuracy

±2℃

±1.5℃

±1℃

Power supply

AC380V

Power

15KW

×

Contact Us